Product Thumbnail

Model 24A Pressure Transducer

0-5 Vdc output, 3 thru 5K psi, Silicon Sensor

Product Thumbnail

Viatran's 24A is one of our most versatile pressure transducers for industrial applications. The 24A measures from 3 PSI to 5000 PSI (0.2 to 345 bar) with standard linearity of ≤±0.25% FSO.


Request a Quote

Order online now

Features

High Accuracy
Many Options available
All Stainless Steel construction
Shunt Calibration circuit option
RoHS Compliant
Low Pressure Applications


Viatran's 24A is one of our most versatile pressure transducers for industrial applications. The 24A measures from 3 PSI to 5000 PSI (0.2 to 345 bar) with standard linearity of ≤±0.25% FSO. Improved linearity of ±0.15% or ±0.10% FSO are available as options. The Model 24A has an 0 - 5 Vdc Output Signal as standard. (Options available)

Typical Applications:

• Engine test stands

• Production test stands

• Hydraulic

• Compressors & Pumps

• Rolling mills

• Die Casting

Contact our Application Engineers today to customize this unit to meet your specific needs.

Performance
Full Scale Pressure Ranges
0-3 thru 5000 PSIG (PSIS FOR >500 PSI) (0.2 thru 345 bar)
0-15 thru 0-5000 PSIA (0-1.0 thru 0-345 bar)
0-15 PSIV (0-1.03 BarV)
Nonlinearity (Best Fit Straight Line)
≤±0.25% FSO
Hysteresis & Repeatability
≤±0.10% FSO
Full Scale Output (FSO)
5Vdc at 70°F (21°C) ±1.0% FSO standard
Resolution
Infinite
Long Term Stability
≤±0.3% FSO per 6 months
Compensated Temperature Range
70°F to 170°F (21°C to 77°C)
Process Media Temperature Range
-40°F to 250°F (-40°C to 121°C)
Ambient Operating Temperature Range
-40°F to 185°F (-40°C to 85°C)
Storage Temperature Limits
-40°F to 250°F (-40°C to 121°C)
Temperature Effect on Zero
≤±2.0% FSO per 100°F
Temperature Effect on Span
≤±2.0% FSO per 100°F
Electrical
Supply Voltage
8 to 30 Vdc at 3.5 mA nominal, 5 mA max
(12 to 30 Vdc for 10 Vdc output option)
Power Supply Regulation
≤±0.01% FSO per volt change over the supply voltage range
Output Signal
0 - 5 Vdc standard (see options)
Zero Adjustment
±5% FSO min
Circuit Protection
Input polarity may be reversed. Output may be short-circuited indefinitely Over voltage protection to 1000 volts according to EN61000-4-5
Insulation Resistance
<5 nSec to case ground
Response Time
<2 mSec to reach 90% of full scale
RFI / EMI Suppression
CE EMC compliant per IEC EN 61326. CE marked
Electrical Connection
Bendix PT02E-10-6P, mates PT06E-10-6S (SR)
Pin Outs
Pin A + Power
Pin B - Power
Pin C + Signal
Pin D - Signal
Pin E No connection
Pin F No connection
Shell Ground
Materials of Construction
Wetted Parts
316 Stainless Steel
Housing
304L SS
Weight
10 oz (283 g)
Identification
Pressure sensitive label
Mechanical
Pressure Connection
1/4" - 18 NPT female
Proof Pressure
≤500 PSI (35 bar) 3 times range or 1,200 PSI (80 bar) max
>500 PSI (35 bar) 3 times range or 9,000 PSI (620 bar) max
Burst Pressure
≤500 PSI (35 bar) 5 times range or 2,400 PSI (170 bar) max
>500 PSI (35 bar) 5 times range or 10,000 PSI (700 bar) max
Pressure Cavity Volume
≤500 PSI (35 bar) 1.5 ml
>500 PSI (35 bar) 1.5 ml
Mounting
May be supported by process piping
Options
BF
(K)PTIH-10-6P
BG
DIN 43650
BL
WK6-32S
BN
(K)PTIH-8-4P
BQ
(K)PT02H-10-6P
BR
CF3102E-14S-6P
DA
Isolated shunt
DC
Extended Compensated Temperature Range (Cold) -40°F to 170°F (-40°C to 77°C)
DG
Improved temp performance to 0.005% FSO per 1°F
DH
Special ranging
DK
Special shunt calibration setting
DM
Modified full scale output
DN
Improved non-linearity
DQ
Cleaning for oxygen service
EA
Special calibration run
ED
Extra improved linearity (±0.10% FSO)
EH
Extended Compensated Temperature Range (Hot) +70°F to 185°F (21°C to 85°C)
LR
Permanent Laser Mark
LV
Externally powered,Optically Isolated Shunt Cal
NH
Customer specified identification
PW
1/8 DIN digital indicator
Y()
Multiple pressure ports available. Consult factory
ZU
Direct Cable (175°F max temperature) (79°C)
Note:
Application of some available options may affect standard performance. Consult your Viatran representative for details.

Model 24A Pressure Transducer

Product Thumbnail

Model 24A Pressure Transducer

0-5 Vdc output, 3 thru 5K psi, Silicon Sensor

Viatran's 24A is one of our most versatile pressure transducers for industrial applications. The 24A measures from 3 PSI to 5000 PSI (0.2 to 345 bar) with standard linearity of ≤±0.25% FSO.


Request a Quote

Performance
Full Scale Pressure Ranges
0-3 thru 5000 PSIG (PSIS FOR >500 PSI) (0.2 thru 345 bar)
0-15 thru 0-5000 PSIA (0-1.0 thru 0-345 bar)
0-15 PSIV (0-1.03 BarV)
Nonlinearity (Best Fit Straight Line)
≤±0.25% FSO
Hysteresis & Repeatability
≤±0.10% FSO
Full Scale Output (FSO)
5Vdc at 70°F (21°C) ±1.0% FSO standard
Resolution
Infinite
Long Term Stability
≤±0.3% FSO per 6 months
Compensated Temperature Range
70°F to 170°F (21°C to 77°C)
Process Media Temperature Range
-40°F to 250°F (-40°C to 121°C)
Ambient Operating Temperature Range
-40°F to 185°F (-40°C to 85°C)
Storage Temperature Limits
-40°F to 250°F (-40°C to 121°C)
Temperature Effect on Zero
≤±2.0% FSO per 100°F
Temperature Effect on Span
≤±2.0% FSO per 100°F

Electrical
Supply Voltage
8 to 30 Vdc at 3.5 mA nominal, 5 mA max
(12 to 30 Vdc for 10 Vdc output option)
Power Supply Regulation
≤±0.01% FSO per volt change over the supply voltage range
Output Signal
0 - 5 Vdc standard (see options)
Zero Adjustment
±5% FSO min
Circuit Protection
Input polarity may be reversed. Output may be short-circuited indefinitely Over voltage protection to 1000 volts according to EN61000-4-5
Insulation Resistance
<5 nSec to case ground
Response Time
<2 mSec to reach 90% of full scale
RFI / EMI Suppression
CE EMC compliant per IEC EN 61326. CE marked
Electrical Connection
Bendix PT02E-10-6P, mates PT06E-10-6S (SR)
Pin Outs
Pin A + Power
Pin B - Power
Pin C + Signal
Pin D - Signal
Pin E No connection
Pin F No connection
Shell Ground

Model 24A Pressure Transducer

High Accuracy
Many Options available
All Stainless Steel construction
Shunt Calibration circuit option
RoHS Compliant
Low Pressure Applications

Viatran's 24A is one of our most versatile pressure transducers for industrial applications. The 24A measures from 3 PSI to 5000 PSI (0.2 to 345 bar) with standard linearity of ≤±0.25% FSO. Improved linearity of ±0.15% or ±0.10% FSO are available as options. The Model 24A has an 0 - 5 Vdc Output Signal as standard. (Options available)

Typical Applications:

• Engine test stands

• Production test stands

• Hydraulic

• Compressors & Pumps

• Rolling mills

• Die Casting

Contact our Application Engineers today to customize this unit to meet your specific needs.

Materials of Construction
Wetted Parts
316 Stainless Steel
Housing
304L SS
Weight
10 oz (283 g)
Identification
Pressure sensitive label

Mechanical
Pressure Connection
1/4" - 18 NPT female
Proof Pressure
≤500 PSI (35 bar) 3 times range or 1,200 PSI (80 bar) max
>500 PSI (35 bar) 3 times range or 9,000 PSI (620 bar) max
Burst Pressure
≤500 PSI (35 bar) 5 times range or 2,400 PSI (170 bar) max
>500 PSI (35 bar) 5 times range or 10,000 PSI (700 bar) max
Pressure Cavity Volume
≤500 PSI (35 bar) 1.5 ml
>500 PSI (35 bar) 1.5 ml
Mounting
May be supported by process piping

Options
BF
(K)PTIH-10-6P
BG
DIN 43650
BL
WK6-32S
BN
(K)PTIH-8-4P
BQ
(K)PT02H-10-6P
BR
CF3102E-14S-6P
DA
Isolated shunt
DC
Extended Compensated Temperature Range (Cold) -40°F to 170°F (-40°C to 77°C)
DG
Improved temp performance to 0.005% FSO per 1°F
DH
Special ranging
DK
Special shunt calibration setting
DM
Modified full scale output
DN
Improved non-linearity
DQ
Cleaning for oxygen service
EA
Special calibration run
ED
Extra improved linearity (±0.10% FSO)
EH
Extended Compensated Temperature Range (Hot) +70°F to 185°F (21°C to 85°C)
LR
Permanent Laser Mark
LV
Externally powered,Optically Isolated Shunt Cal
NH
Customer specified identification
PW
1/8 DIN digital indicator
Y()
Multiple pressure ports available. Consult factory
ZU
Direct Cable (175°F max temperature) (79°C)
Note:
Application of some available options may affect standard performance. Consult your Viatran representative for details.

Model 24A Pressure Transducer

Blueprint Image

By clicking "Accept" or continuing to use our site, you acknowledge that you accept our Privacy Policy and Terms of Use. We also use first and third-party cookies to enhance site navigation, analyze site usage, and assist our marketing efforts in accordance with our Privacy Policy.