Model 118 Pressure Transmitter
mv/V output, Industrial Transmitter

A field-proven, rugged pressure transmitter for a variety of industrial applications.
Request a Quote
Features
All Stainless Steel construction
Shunt Calibration circuit option
PERFORMANCE
Full Scale Pressure Range
0-5, 10, 15 PSIV, 0-5, 10, 15, 20, 25, 30, 50, 75, 100, 150, 200, 300, 400, 500, 750, 1K, 1500, 2K, 3K, 4K, 5K 6K 7500, 10K and 15K PSIG, PSIA
(PSID 0-6K max, 500 PSI max on reference side)
Non-Linearity (Best Fit Straight Line)
50-10K PSI
≤0.15% FSO
5-40 PSI, 15K PSI
≤0.25% FSO
Hysteresis
≤0.25% FSO
Repeatability
≤0.1% FSO
Full Scale Output (FSO)
2-3 mV/V
Resolution
Infinite
Long-Term Stability
≤±0.25% FSO per 6 months
Response Time
≤1 mSec to reach 90% FSO
Zero Balance
Fixed at 0 mV ±2% FSO at 70°F (21°C)
Temperature Effect on Zero
≤±2.0% FSO per 100°F (37°C)
Temperature Effect on Span
≤±1.0% FSO per 100°F (37°C)
Compensated Temperature Range
70°F to 170°F (56°C to 76°C)
Operating Temperature Range
-40°F to 250°F (-40°C to 121°C)
Storage Temperature Range
-50°F to 250°F (-45°C to 121°C)
ELECTRICAL
Supply Voltage
10 to 15 Vdc
Power Supply Regulation
N/A
Output Signal
0-5 & 0-10 PSI
1.6 to 2.4 mV/V; 2 mV/V typical
0-15 PSI and Above
2.4 to 3.6 mV/V; 2 mV/V typical
Load Impedance
N/A
Circuit Protection
None
Range Calibration Signal
80% FSO by applying a specified resistance across Pins 2 & 4 of the connector
Span Adjustment
None
Bridge Resistance
350 Ohms nominal
Insulation Resistance
>1000 MegOhms to case ground
Electrical connection
Cannon WK4-32S
PIN OUTS
PIN 1
+Power
PIN 2
-Power
PIN3
+Signal
PIN 4
-Signal
MECHANICAL
Pressure Connection
1/4” NPT (F)
Proof Pressure
1.5 times FSPR or 20K PSI
Burst Pressure
5 times FSPR or 22K PSI
Weight
25 oz nominal
Enclosure Materials
15-5 PH, 303 and 304 stainless steel
Identification
Laser etched onto body
Measured Fluids
Any gas or liquid compatible with 15-5 PH, 17-7 PH, 303 SS and B Buna N O-ring
Position Sensitivity
Mounts in any position with no effect on zero
OPTIONS
B( )
Alternate electrical connector (or wiring)
Y( )
Alternate pressure connection
G( )
Alternate O-ring material
DB
Increased overpressure rating
DC
Extended temperature operation
DD
Standardized output
DE
Internal calibration
DF
Bleed port
DG
Improved temperature compensation
DH
Special pressure range
DM
Modified FSO (0 to 10 V out requires 15 Vdc input min)
DN
Improved accuracy
DP
Submersible housing / 8’ direct coupled cable
DQ
Cleaning for oxygen service
EA
Special calibration
NH
Customer specified identification
PW
1/8 DIN digital indicator

You may also consider...

Model 118 Pressure Transmitter

Model 118 Pressure Transmitter
mv/V output, Industrial Transmitter
A field-proven, rugged pressure transmitter for a variety of industrial applications.
Request a Quote
PERFORMANCE
Full Scale Pressure Range
0-5, 10, 15 PSIV, 0-5, 10, 15, 20, 25, 30, 50, 75, 100, 150, 200, 300, 400, 500, 750, 1K, 1500, 2K, 3K, 4K, 5K 6K 7500, 10K and 15K PSIG, PSIA
(PSID 0-6K max, 500 PSI max on reference side)
Non-Linearity (Best Fit Straight Line)
50-10K PSI
≤0.15% FSO
5-40 PSI, 15K PSI
≤0.25% FSO
Hysteresis
≤0.25% FSO
Repeatability
≤0.1% FSO
Full Scale Output (FSO)
2-3 mV/V
Resolution
Infinite
Long-Term Stability
≤±0.25% FSO per 6 months
Response Time
≤1 mSec to reach 90% FSO
Zero Balance
Fixed at 0 mV ±2% FSO at 70°F (21°C)
Temperature Effect on Zero
≤±2.0% FSO per 100°F (37°C)
Temperature Effect on Span
≤±1.0% FSO per 100°F (37°C)
Compensated Temperature Range
70°F to 170°F (56°C to 76°C)
Operating Temperature Range
-40°F to 250°F (-40°C to 121°C)
Storage Temperature Range
-50°F to 250°F (-45°C to 121°C)
ELECTRICAL
Supply Voltage
10 to 15 Vdc
Power Supply Regulation
N/A
Output Signal
0-5 & 0-10 PSI
1.6 to 2.4 mV/V; 2 mV/V typical
0-15 PSI and Above
2.4 to 3.6 mV/V; 2 mV/V typical
Load Impedance
N/A
Circuit Protection
None
Range Calibration Signal
80% FSO by applying a specified resistance across Pins 2 & 4 of the connector
Span Adjustment
None
Bridge Resistance
350 Ohms nominal
Insulation Resistance
>1000 MegOhms to case ground
Electrical connection
Cannon WK4-32S
PIN OUTS
PIN 1
+Power
PIN 2
-Power
PIN3
+Signal
PIN 4
-Signal
Model 118 Pressure Transmitter
All Stainless Steel construction
Shunt Calibration circuit option
MECHANICAL
Pressure Connection
1/4” NPT (F)
Proof Pressure
1.5 times FSPR or 20K PSI
Burst Pressure
5 times FSPR or 22K PSI
Weight
25 oz nominal
Enclosure Materials
15-5 PH, 303 and 304 stainless steel
Identification
Laser etched onto body
Measured Fluids
Any gas or liquid compatible with 15-5 PH, 17-7 PH, 303 SS and B Buna N O-ring
Position Sensitivity
Mounts in any position with no effect on zero
OPTIONS
B( )
Alternate electrical connector (or wiring)
Y( )
Alternate pressure connection
G( )
Alternate O-ring material
DB
Increased overpressure rating
DC
Extended temperature operation
DD
Standardized output
DE
Internal calibration
DF
Bleed port
DG
Improved temperature compensation
DH
Special pressure range
DM
Modified FSO (0 to 10 V out requires 15 Vdc input min)
DN
Improved accuracy
DP
Submersible housing / 8’ direct coupled cable
DQ
Cleaning for oxygen service
EA
Special calibration
NH
Customer specified identification
PW
1/8 DIN digital indicator
Model 118 Pressure Transmitter
Model 118 Pressure Transmitter
