Model 118 Pressure Transmitter
mv/V output, Industrial Transmitter
            A field-proven, rugged pressure transmitter for a variety of industrial applications.
Request a Quote
Features
                    
                    All Stainless Steel construction
                
                
                
                    
                    Shunt Calibration circuit option
                
                
              PERFORMANCE
                    Full Scale Pressure Range
                            0-5, 10, 15 PSIV, 0-5, 10, 15, 20, 25, 30, 50, 75, 100, 150, 200, 300, 400, 500, 750, 1K, 1500, 2K, 3K, 4K, 5K 6K 7500, 10K and 15K PSIG, PSIA
                            (PSID 0-6K max, 500 PSI max on reference side)
                        
                        
                        
                        
                        Non-Linearity (Best Fit Straight Line)
                            50-10K PSI
                            ≤0.15% FSO
                        
                        
                        
                        
                        
                            5-40 PSI, 15K PSI
                            ≤0.25% FSO
                        
                        
                        
                        
                        Hysteresis
                            ≤0.25% FSO
                            
                        
                        
                        
                        
                        Repeatability
                            ≤0.1% FSO
                            
                        
                        
                        
                        
                        Full Scale Output (FSO)
                            2-3 mV/V
                            
                        
                        
                        
                        
                        Resolution
                            Infinite
                            
                        
                        
                        
                        
                        Long-Term Stability
                            ≤±0.25% FSO per 6 months
                            
                        
                        
                        
                        
                        Response Time
                            ≤1 mSec to reach 90% FSO
                            
                        
                        
                        
                        
                        Zero Balance
                            Fixed at 0 mV ±2% FSO at 70°F (21°C)
                            
                        
                        
                        
                        
                        Temperature Effect on Zero
                            ≤±2.0% FSO per 100°F (37°C)
                            
                        
                        
                        
                        
                        Temperature Effect on Span
                            ≤±1.0% FSO per 100°F (37°C)
                            
                        
                        
                        
                        
                        Compensated Temperature Range
                            70°F to 170°F (56°C to 76°C)
                            
                        
                        
                        
                        
                        Operating Temperature Range
                            -40°F to 250°F (-40°C to 121°C)
                            
                        
                        
                        
                        
                        Storage Temperature Range
                            -50°F to 250°F (-45°C to 121°C)
                            
                        
                        
                        
                      ELECTRICAL
                    Supply Voltage
                            10 to 15 Vdc
                            
                        
                        
                        
                        
                        Power Supply Regulation
                            N/A
                            
                        
                        
                        
                        
                        Output Signal
                            0-5 & 0-10 PSI
                            1.6 to 2.4 mV/V; 2 mV/V typical
                        
                        
                        
                        
                        
                            0-15 PSI and Above
                            2.4 to 3.6 mV/V; 2 mV/V typical
                        
                        
                        
                        
                        Load Impedance
                            N/A
                            
                        
                        
                        
                        
                        Circuit Protection
                            None
                            
                        
                        
                        
                        
                        Range Calibration Signal
                            80% FSO by applying a specified resistance across Pins 2 & 4 of the connector
                            
                        
                        
                        
                        
                        Span Adjustment
                            None
                            
                        
                        
                        
                        
                        Bridge Resistance
                            350 Ohms nominal
                            
                        
                        
                        
                        
                        Insulation Resistance
                            >1000 MegOhms to case ground
                            
                        
                        
                        
                        
                        Electrical connection
                            Cannon WK4-32S
                            
                        
                        
                        
                        
                        PIN OUTS
                            PIN 1
                            +Power
                        
                        
                        
                        
                        
                            PIN 2
                            -Power
                        
                        
                        
                        
                        
                            PIN3
                            +Signal
                        
                        
                        
                        
                        
                            PIN 4
                            -Signal
                        
                        
                        
                      MECHANICAL
                    Pressure Connection
                            1/4” NPT (F)
                            
                        
                        
                        
                        
                        Proof Pressure
                            1.5 times FSPR or 20K PSI
                            
                        
                        
                        
                        
                        Burst Pressure
                            5 times FSPR or 22K PSI
                            
                        
                        
                        
                        
                        Weight
                            25 oz nominal
                            
                        
                        
                        
                        
                        Enclosure Materials
                            15-5 PH, 303 and 304 stainless steel
                            
                        
                        
                        
                        
                        Identification
                            Laser etched onto body
                            
                        
                        
                        
                        
                        Measured Fluids
                            Any gas or liquid compatible with 15-5 PH, 17-7 PH, 303 SS and B Buna N O-ring
                            
                        
                        
                        
                        
                        Position Sensitivity
                            Mounts in any position with no effect on zero
                            
                        
                        
                        
                      OPTIONS
                    B( )
                            Alternate electrical connector (or wiring)
                            
                        
                        
                        
                        
                        Y( )
                            Alternate pressure connection
                            
                        
                        
                        
                        
                        G( )
                            Alternate O-ring material
                            
                        
                        
                        
                        
                        DB
                            Increased overpressure rating
                            
                        
                        
                        
                        
                        DC
                            Extended temperature operation
                            
                        
                        
                        
                        
                        DD
                            Standardized output
                            
                        
                        
                        
                        
                        DE
                            Internal calibration
                            
                        
                        
                        
                        
                        DF
                            Bleed port
                            
                        
                        
                        
                        
                        DG
                            Improved temperature compensation
                            
                        
                        
                        
                        
                        DH
                            Special pressure range
                            
                        
                        
                        
                        
                        DM
                            Modified FSO (0 to 10 V out requires 15 Vdc input min)
                            
                        
                        
                        
                        
                        DN
                            Improved accuracy
                            
                        
                        
                        
                        
                        DP
                            Submersible housing / 8’ direct coupled cable
                            
                        
                        
                        
                        
                        DQ
                            Cleaning for oxygen service
                            
                        
                        
                        
                        
                        EA
                            Special calibration
                            
                        
                        
                        
                        
                        NH
                            Customer specified identification
                            
                        
                        
                        
                        
                        PW
                            1/8 DIN digital indicator
                            
                        
                        
                        
                    
        You may also consider...
		Model 118 Pressure Transmitter
			Model 118 Pressure Transmitter
mv/V output, Industrial Transmitter
A field-proven, rugged pressure transmitter for a variety of industrial applications.
Request a Quote
PERFORMANCE
					Full Scale Pressure Range
							0-5, 10, 15 PSIV, 0-5, 10, 15, 20, 25, 30, 50, 75, 100, 150, 200, 300, 400, 500, 750, 1K, 1500, 2K, 3K, 4K, 5K 6K 7500, 10K and 15K PSIG, PSIA
							(PSID 0-6K max, 500 PSI max on reference side)
						
						  
						
						Non-Linearity (Best Fit Straight Line)
							50-10K PSI
							≤0.15% FSO
						
						  
						
							5-40 PSI, 15K PSI
							≤0.25% FSO
						
						  
						
						Hysteresis
							≤0.25% FSO
							
						
						  
						
						Repeatability
							≤0.1% FSO
							
						
						  
						
						Full Scale Output (FSO)
							2-3 mV/V
							
						
						  
						
						Resolution
							Infinite
							
						
						  
						
						Long-Term Stability
							≤±0.25% FSO per 6 months
							
						
						  
						
						Response Time
							≤1 mSec to reach 90% FSO
							
						
						  
						
						Zero Balance
							Fixed at 0 mV ±2% FSO at 70°F (21°C)
							
						
						  
						
						Temperature Effect on Zero
							≤±2.0% FSO per 100°F (37°C)
							
						
						  
						
						Temperature Effect on Span
							≤±1.0% FSO per 100°F (37°C)
							
						
						  
						
						Compensated Temperature Range
							70°F to 170°F (56°C to 76°C)
							
						
						  
						
						Operating Temperature Range
							-40°F to 250°F (-40°C to 121°C)
							
						
						  
						
						Storage Temperature Range
							-50°F to 250°F (-45°C to 121°C)
							
						
						 
						ELECTRICAL
					Supply Voltage
							10 to 15 Vdc
							
						
						  
						
						Power Supply Regulation
							N/A
							
						
						  
						
						Output Signal
							0-5 & 0-10 PSI
							1.6 to 2.4 mV/V; 2 mV/V typical
						
						  
						
							0-15 PSI and Above
							2.4 to 3.6 mV/V; 2 mV/V typical
						
						  
						
						Load Impedance
							N/A
							
						
						  
						
						Circuit Protection
							None
							
						
						  
						
						Range Calibration Signal
							80% FSO by applying a specified resistance across Pins 2 & 4 of the connector
							
						
						  
						
						Span Adjustment
							None
							
						
						  
						
						Bridge Resistance
							350 Ohms nominal
							
						
						  
						
						Insulation Resistance
							>1000 MegOhms to case ground
							
						
						  
						
						Electrical connection
							Cannon WK4-32S
							
						
						  
						
						PIN OUTS
							PIN 1
							+Power
						
						  
						
							PIN 2
							-Power
						
						  
						
							PIN3
							+Signal
						
						  
						
							PIN 4
							-Signal
						
						 
						Model 118 Pressure Transmitter
							
							All Stainless Steel construction
						
					
						
							
							Shunt Calibration circuit option
						
					
				MECHANICAL
					Pressure Connection
                                1/4” NPT (F)
                                
                            
						  
                        
                            
                            Proof Pressure
                                1.5 times FSPR or 20K PSI
                                
                            
						  
                        
                            
                            Burst Pressure
                                5 times FSPR or 22K PSI
                                
                            
						  
                        
                            
                            Weight
                                25 oz nominal
                                
                            
						  
                        
                            
                            Enclosure Materials
                                15-5 PH, 303 and 304 stainless steel
                                
                            
						  
                        
                            
                            Identification
                                Laser etched onto body
                                
                            
						  
                        
                            
                            Measured Fluids
                                Any gas or liquid compatible with 15-5 PH, 17-7 PH, 303 SS and B Buna N O-ring
                                
                            
						  
                        
                            
                            Position Sensitivity
                                Mounts in any position with no effect on zero
                                
                            
						 
						OPTIONS
					B( )
                                Alternate electrical connector (or wiring)
                                
                            
						  
                        
                            
                            Y( )
                                Alternate pressure connection
                                
                            
						  
                        
                            
                            G( )
                                Alternate O-ring material
                                
                            
						  
                        
                            
                            DB
                                Increased overpressure rating
                                
                            
						  
                        
                            
                            DC
                                Extended temperature operation
                                
                            
						  
                        
                            
                            DD
                                Standardized output
                                
                            
						  
                        
                            
                            DE
                                Internal calibration
                                
                            
						  
                        
                            
                            DF
                                Bleed port
                                
                            
						  
                        
                            
                            DG
                                Improved temperature compensation
                                
                            
						  
                        
                            
                            DH
                                Special pressure range
                                
                            
						  
                        
                            
                            DM
                                Modified FSO (0 to 10 V out requires 15 Vdc input min)
                                
                            
						  
                        
                            
                            DN
                                Improved accuracy
                                
                            
						  
                        
                            
                            DP
                                Submersible housing / 8’ direct coupled cable
                                
                            
						  
                        
                            
                            DQ
                                Cleaning for oxygen service
                                
                            
						  
                        
                            
                            EA
                                Special calibration
                                
                            
						  
                        
                            
                            NH
                                Customer specified identification
                                
                            
						  
                        
                            
                            PW
                                1/8 DIN digital indicator
                                
                            
						 
						Model 118 Pressure Transmitter
Model 118 Pressure Transmitter
		
                        