Product Thumbnail

Model 59P Level Transmitter

0-13' thru 335' WC, PUR Cable Standard, PP-HT Housing, Ceramic Sensor, Lowest Cost

Product Thumbnail

The Model 59P Submersible Level Transmitter provides Depth and Level measurements while submerged in harsh or aggressive media. Well suited for chemical tank volume or level monitoring.


Request a Quote

Features

IP-68 Rated
RoHS Compliant
Low Pressure Applications
Polypropylene - High Temperature Body


The Model 59P General Purpose Level Transmitter has a 1.38" diameter Polypropylene High Temperature (PP-HT) housing and ceramic sensor.  Polyurethane cable is standard.  Different cable materials and o-rings are available.

Use it to measure Liquid Level and Depth for Water and Waste Water applications, Lift Stations, Reservoirs and Dams, Rivers, Holding Ponds, Wells, In-ground / Above Ground Tanks and with Inventory Tank Gauging.

Viatran also offers a complete range of accessories for use in level applications such as a surge protector, cable hangers and weights, meters and junction boxes.

 

Performance
Pressure Ranges
0-13 Feet W.C. to 0-335 Feet W.C.
Combined Accuracy (Non-Linearity, Hysteresis, Repeatability)
≤±0.50% FSO for ranges < 15 Ft. W.C.
Compensated Temperature Range
13° to 158° F (-25 to 70° C)
Operating Temperature Range
32° to 122° F (0 to 50° C) Note: Medium must not freeze near sensor
Storage Temperature Range
14° to 122° F (-10 to 50° C)
Long Term Stability (%FSO)
≤±0.1% FSO / year at reference conditions
Thermal Effect on Zero
≤±0.8% FSO per 100° F
Thermal Effect on Span
≤±0.12% FSO per 100° F
Temperature Accuracy
≤±0.12% FSO per 100° F
Electrical
Output Signal
4-20 mA
Supply Voltage
8 - 32Vdc
Power Supply Regulation
<±005% FSO per volt
Circuit Protection
Reverse polarity protected, CE marked
RFI/EMI
CE EMC cmpliant as per IEC EN 61326
Voltage Spike Protection
Withstand 1000 volt spike per EN 61000
Response Time
<10mSec
Mechanical
Pressure Connection
Open Face
Ingress Protection
IP 68
Overpressure Limit􀀀
1.6x Minimum
Weight
0.5 lbs. (without cable)
Materials of Construction
Housing
PP-HT (Polypropylene High Temperature)
Sensor Diaphragm
Ceramic Al2O3 96%
Cable
PUR, PVC, or FEP (customer must specify)
Seals
FKM or EPDM (customer must specify)
Options
EA
Special Calibration Run
PW
Calibrate item with meter/display

Model 59P Level Transmitter

Product Thumbnail

Model 59P Level Transmitter

0-13' thru 335' WC, PUR Cable Standard, PP-HT Housing, Ceramic Sensor, Lowest Cost

The Model 59P Submersible Level Transmitter provides Depth and Level measurements while submerged in harsh or aggressive media. Well suited for chemical tank volume or level monitoring.


Request a Quote

Performance
Pressure Ranges
0-13 Feet W.C. to 0-335 Feet W.C.
Combined Accuracy (Non-Linearity, Hysteresis, Repeatability)
≤±0.50% FSO for ranges < 15 Ft. W.C.
Compensated Temperature Range
13° to 158° F (-25 to 70° C)
Operating Temperature Range
32° to 122° F (0 to 50° C) Note: Medium must not freeze near sensor
Storage Temperature Range
14° to 122° F (-10 to 50° C)
Long Term Stability (%FSO)
≤±0.1% FSO / year at reference conditions
Thermal Effect on Zero
≤±0.8% FSO per 100° F
Thermal Effect on Span
≤±0.12% FSO per 100° F
Temperature Accuracy
≤±0.12% FSO per 100° F

Electrical
Output Signal
4-20 mA
Supply Voltage
8 - 32Vdc
Power Supply Regulation
<±005% FSO per volt
Circuit Protection
Reverse polarity protected, CE marked
RFI/EMI
CE EMC cmpliant as per IEC EN 61326
Voltage Spike Protection
Withstand 1000 volt spike per EN 61000
Response Time
<10mSec

Model 59P Level Transmitter

IP-68 Rated
RoHS Compliant
Low Pressure Applications
Polypropylene - High Temperature Body

The Model 59P General Purpose Level Transmitter has a 1.38" diameter Polypropylene High Temperature (PP-HT) housing and ceramic sensor.  Polyurethane cable is standard.  Different cable materials and o-rings are available.

Use it to measure Liquid Level and Depth for Water and Waste Water applications, Lift Stations, Reservoirs and Dams, Rivers, Holding Ponds, Wells, In-ground / Above Ground Tanks and with Inventory Tank Gauging.

Viatran also offers a complete range of accessories for use in level applications such as a surge protector, cable hangers and weights, meters and junction boxes.

 

Mechanical
Pressure Connection
Open Face
Ingress Protection
IP 68
Overpressure Limit􀀀
1.6x Minimum
Weight
0.5 lbs. (without cable)

Materials of Construction
Housing
PP-HT (Polypropylene High Temperature)
Sensor Diaphragm
Ceramic Al2O3 96%
Cable
PUR, PVC, or FEP (customer must specify)
Seals
FKM or EPDM (customer must specify)

Options
EA
Special Calibration Run
PW
Calibrate item with meter/display

Model 59P Level Transmitter

Model 59P Level Transmitter


By clicking "Accept" or continuing to use our site, you acknowledge that you accept our Privacy Policy and Terms of Use. We also use first and third-party cookies to enhance site navigation, analyze site usage, and assist our marketing efforts in accordance with our Privacy Policy.