572 is designed with a secondary containment pressure feature which can withstand 40K of pressure. Available ranges from 0-100 thru 20K, designed for safety critical applications in oil services. Sealed external adjustments are standard with this model, and a wide variety of electrical and process connections are available as options.


Request a Quote

Features

ShuntCal
IP-68 Rated
High Pressure Applications


Viatran's 572 pressure transmitter is designed specifically for secondary containment applications in oil services applications.

A sealed gage or absolute pressure reference is available for medium to very high pressures, with a containment pressure of 40,000 PSI. The model 572 pressure transducer withstands harsh atmospheres and is built to be submersed in up to 100 feet of water.

The 572 pressure transmitter can be supplied with FM approves for explosionproof, intrinsic safety or non-incendive. The 572 pressure sensor can also be supplied with ATEX intrinsic safety or flameproof or CSA intrinsic safety or explosionproof approvals.

The standard 572 pressure transmitter has an all welded construction that features 1/4-18 NPT thread for installation in low pressure applications and the F-250-C autoclave fitting for the high pressure applications. Optional pressure fittings and electrical terminations are available.

Performance
Full Scale Pressure Range (FSPR)
0-100, 150, 300, 500, 1K, 2K, 3K, 5K, 7500, 10K, 15K, 20K PSIA, PSIS, PSIG
Combined Accuracy (Non-Linearity, Hysteresis, Repeatability)
≤±0.25 FSO
Full Scale Output (FSO)
16 mA at 70°F
Resolution
Infinite
Long Term Stability
≤±0.25% FSO per 6 months
Response Time (Mechanical and Electrical Combined)
≤20mSec to reach 90% of FSO
Temperature Effect on Zero
≤±1% FSO per 100°F
Temperature Effect on Span
≤±1% FSO per 100°F
Operating Temperature Range
0°F to +180°F
Non-operating Temperature Range
-65°F to +250°F
Electrical
Supply Voltage
12 to 40 VDC
Power Supply Regulation
≤±0.02$ FSO per volt
Output Signal
4-20 mA at 70°F
Load Impedance
1500 Ohms maximum at 40 VDC
Zero Adjustment Elevation
-100% of FSO
Zero Supression
+50% of FSO
Span Adjustment
Rangeable down 5:1 from standard range
Range Calibration Signal
20% ±0.1% of FSPR, externally switched. Exact signal-pressure correlation provided with each unit.
Circuit Protection
Varistor protected across the input leads for surges above 40V and currents to 250A peak with a pulse width of 8x20 µSec. Reverse polarity protected.
Bridge Resistance
5K Ohms nominal
Insulation Resistance
>200 MegOhms to case ground
RFI/EMI Suppression
Negligible effect to 500MHz at 5W direct contact
Electrical Connection
1/2" NPT Male (conduit connection)
Wire Color Codes
Red
+Power/Signal
Black
-Power/Signal
Green
Case Ground
Mechanical
Pressure Connections
Ranges <10K PSI
1/4" NPT female
Ranges >10K PSI
Autoclave F-250–C
Proof Pressure
1.5 times FSPR or 25K PSI, whichever is less
Burst Pressure Sensor
0-100 thru 0-3K PSI
>5 times FSPR
Up to 0-5K PSI
>4 times FSPR
Up to 0-10K PSI
>2.7 times FSPR
Up to 0-20K PSI
>2 times FSPR
Secondary Containment Vessel
>40K PSI
Shock Limitation
100 G’s
Weight
4 lbs. 8 oz.
Materials of Construction
Wetted Materials
Hastelloy C-276
Secondary Containment Vessel
Hastelloy C-276, Molybdenum wire, and glass; Inconel X-750
Housing
Hastelloy C-276 and 316 SS; Inconel X-750
Options
DG
Improved temperature performance
DK
Special calibration shunt ___%
DQ
Cleaning for Oxygen service
EA
Special calibration
NH
Customer specified identification
NSR
Non-standard range
PW
1/8 DIN digital indicator
Note:
Application of some available options may affect standard performance. Consult your Viatran representative for details.

Model 572 Pressure Sensor

Product Thumbnail

Model 572 Pressure Sensor

Secondary Containment to 40K, Hastelloy Wetted Materials, Hazardous Location Approvals

572 is designed with a secondary containment pressure feature which can withstand 40K of pressure. Available ranges from 0-100 thru 20K, designed for safety critical applications in oil services. Sealed external adjustments are standard with this model, and a wide variety of electrical and process connections are available as options.


Request a Quote

Performance
Full Scale Pressure Range (FSPR)
0-100, 150, 300, 500, 1K, 2K, 3K, 5K, 7500, 10K, 15K, 20K PSIA, PSIS, PSIG
Combined Accuracy (Non-Linearity, Hysteresis, Repeatability)
≤±0.25 FSO
Full Scale Output (FSO)
16 mA at 70°F
Resolution
Infinite
Long Term Stability
≤±0.25% FSO per 6 months
Response Time (Mechanical and Electrical Combined)
≤20mSec to reach 90% of FSO
Temperature Effect on Zero
≤±1% FSO per 100°F
Temperature Effect on Span
≤±1% FSO per 100°F
Operating Temperature Range
0°F to +180°F
Non-operating Temperature Range
-65°F to +250°F

Electrical
Supply Voltage
12 to 40 VDC
Power Supply Regulation
≤±0.02$ FSO per volt
Output Signal
4-20 mA at 70°F
Load Impedance
1500 Ohms maximum at 40 VDC
Zero Adjustment Elevation
-100% of FSO
Zero Supression
+50% of FSO
Span Adjustment
Rangeable down 5:1 from standard range
Range Calibration Signal
20% ±0.1% of FSPR, externally switched. Exact signal-pressure correlation provided with each unit.
Circuit Protection
Varistor protected across the input leads for surges above 40V and currents to 250A peak with a pulse width of 8x20 µSec. Reverse polarity protected.
Bridge Resistance
5K Ohms nominal
Insulation Resistance
>200 MegOhms to case ground
RFI/EMI Suppression
Negligible effect to 500MHz at 5W direct contact
Electrical Connection
1/2" NPT Male (conduit connection)
Wire Color Codes
Red
+Power/Signal
Black
-Power/Signal
Green
Case Ground

Model 572 Pressure Sensor

ShuntCal
IP-68 Rated
High Pressure Applications

Viatran's 572 pressure transmitter is designed specifically for secondary containment applications in oil services applications.

A sealed gage or absolute pressure reference is available for medium to very high pressures, with a containment pressure of 40,000 PSI. The model 572 pressure transducer withstands harsh atmospheres and is built to be submersed in up to 100 feet of water.

The 572 pressure transmitter can be supplied with FM approves for explosionproof, intrinsic safety or non-incendive. The 572 pressure sensor can also be supplied with ATEX intrinsic safety or flameproof or CSA intrinsic safety or explosionproof approvals.

The standard 572 pressure transmitter has an all welded construction that features 1/4-18 NPT thread for installation in low pressure applications and the F-250-C autoclave fitting for the high pressure applications. Optional pressure fittings and electrical terminations are available.

Mechanical
Pressure Connections
Ranges <10K PSI
1/4" NPT female
Ranges >10K PSI
Autoclave F-250–C
Proof Pressure
1.5 times FSPR or 25K PSI, whichever is less
Burst Pressure Sensor
0-100 thru 0-3K PSI
>5 times FSPR
Up to 0-5K PSI
>4 times FSPR
Up to 0-10K PSI
>2.7 times FSPR
Up to 0-20K PSI
>2 times FSPR
Secondary Containment Vessel
>40K PSI
Shock Limitation
100 G’s
Weight
4 lbs. 8 oz.

Materials of Construction
Wetted Materials
Hastelloy C-276
Secondary Containment Vessel
Hastelloy C-276, Molybdenum wire, and glass; Inconel X-750
Housing
Hastelloy C-276 and 316 SS; Inconel X-750

Options
DG
Improved temperature performance
DK
Special calibration shunt ___%
DQ
Cleaning for Oxygen service
EA
Special calibration
NH
Customer specified identification
NSR
Non-standard range
PW
1/8 DIN digital indicator
Note: